modelMetalWallFV

Generic metal wall model with Nw finite volumes

Extends from ThermoPower.Icons.MetalWall.

Information

Finite volumes 1D model of a generic wall for 1D heat exchangers.

The heat capacity of the wall is accounted for, and lumped half-way between the inner and outer surfaces.

The thermal resistance of the wall is optionally accounted for by setting WallRes = true; in that case, the total heat conductance of the outer and inner half-layers of the wall must then be set. For a flat (or approximately flat) wall with surface S, thickness d and conductivity lambda, both parameters are equal to 2*S*lambda/d.

Modelling options

The following options are available:

  • WallRes = false: the thermal resistance of the wall is neglected.
  • WallRes = true: the thermal resistance of the wall is accounted for.

Parameters

TypeNameDefaultDescription
IntegerNw1Number of volumes on the wall ports
SI.MassMMass
SI.SpecificHeatCapacitycmSpecific heat capacity of metal
SI.HeatCapacityCmM*cmHeat capacity of the wall
BooleanWallResfalseWall thermal resistance accounted for
SI.ThermalConductanceUA_ext0Equivalent thermal conductance of outer half-wall
SI.ThermalConductanceUA_intUA_extEquivalent thermal conductance of inner half-wall
RealpiModelica.Constants.pi
Initialisation
SI.TemperatureTstartbar300Average temperature
SI.TemperatureTstart1TstartbarTemperature start value - first volume
SI.TemperatureTstartNTstartbarTemperature start value - last volume
SI.Temperature[Nw]TvolstartFunctions.linspaceExt(Tstart1, TstartN, Nw)
ThermoPower.Choices.Init.OptionsinitOptsystem.initOptInitialisation option

Connectors

TypeNameDefaultDescription
ThermoPower.Thermal.DHTVolumesintInternal surface
ThermoPower.Thermal.DHTVolumesextExternal surface

Components

TypeNameDefaultDescription
ThermoPower.SystemsystemSystem wide properties
Units.AbsoluteTemperature[Nw]TvolVolume temperatures

Revisions