modelTempSource1DFEM

Distributed Temperature Source for FEM models

Extends from Icons.HeatFlow.

Information

Model of an ideal 1D uniform temperature source. The actual temperature can be provided by one of the following ways:

  • by using the temperature signal connector, if the flag useTin = true (default).
  • by using the parameter T, if the flag useTin = false.

Parameters

TypeNameDefaultDescription
IntegerN2Number of nodes
BooleanuseTintrueuse input for the temperature value
SI.TemperatureT293.15temperature value (if exetrnal input is not used)

Connectors

TypeNameDefaultDescription
Thermal.DHTNodeswall
Modelica.Blocks.Interfaces.RealInputtemperature

Revisions