modelFlowSplit
Extends from Icons.Water.FlowSplit.
Information
This component allows to split a single flow in two ones. The model is based on mass and energy balance equations, without any mass or energy buildup, and without any pressure drop between the inlet and the outlets.
Since stream connectors are used in the library, this component is actually not necessary to handle a three-way connection. It can be used for a finer tuning of the simplified model for initialization using homotopy, in particularly hard-to-initialize systems, and it is included in the library for backwards compatibility.
Modelling options
If rev_in1, rev_out1 or rev_out2 is true, the respective flows reversal is allowed. If at least ona among these parameters is false, it is possible to set checkFlowDirection.
If checkFlowDirection is true, when the flow reversal happen where it is not allowed, the error message is showed.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Boolean | allowFlowReversal | system.allowFlowReversal | = true to allow flow reversal, false restricts to design direction |
| SI.MassFlowRate | wzero | 1e-9 | Small flowrate to avoid singularity in computing the outlet enthalpy |
| Boolean | rev_in1 | allowFlowReversal | Allow flow reversal at in1 |
| Boolean | rev_out1 | allowFlowReversal | Allow flow reversal at out1 |
| Boolean | rev_out2 | allowFlowReversal | Allow flow reversal at out2 |
| Boolean | checkFlowDirection | false | Check flow direction |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| FlangeA | in1 | ||
| FlangeB | out1 | ||
| FlangeB | out2 |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| ThermoPower.System | system | System wide properties |
Contents
| Name | Description |
|---|---|
Revisions
- 30 Oct 2014
by Francesco Casella:
Bug fixing. - 23 May 2008
by Luca Savoldelli:
Allow flows reversal option added. - 16 Dec 2004
by Francesco Casella:
Standard medium definition added. - 1 Oct 2003
by Francesco Casella: