modelAccelerationBoundary

Sets and broadcasts acceleration vector, default is fixed in negative z-direction with length of DropOfCommons.g

Extends from ThermofluidStream.Utilities.DropOfCommonsPlus (Extend this to use 'dropOfCommons', 'instanceName', 'displayInstanceName' and 'displayParameters').

Information


This component sets and broadcasts an acceleration vector. The default is fixed in negative z-direction with length of DropOfCommons.g. The acceleration can be set either by inputs or real expressions.

Beware: This is a new addition to the library. It may be subject to design reconsiderations in future versions.

Parameters

TypeNameDefaultDescription
StringinstanceName (from DropOfCommonsPlus)getInstanceName()Instance name
BooleansetFromInputsfalse
Layout
BooleandisplayInstanceName (from DropOfCommonsPlus)dropOfCommons.displayInstanceNames= true, if instance name is displayed
BooleandisplayParameters (from DropOfCommonsPlus)dropOfCommons.displayParameters= true, if displaying parameters is enabled

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputux
Modelica.Blocks.Interfaces.RealInputuy
Modelica.Blocks.Interfaces.RealInputuz

Components

TypeNameDefaultDescription
SI.Accelerationax0
SI.Accelerationay0
SI.Accelerationaz-dropOfCommons.g
SI.Acceleration[3]a

Revisions

Author: Ingela Lind, M Sc, Ph D, Technical Fellow, Simulation and Thermal Analysis, Vehicle Systems, SAAB Aerosystems, 2024