modelNaturalGasVolumeFlowSTP

Model for describing the average volume flow of natural gas

Extends from TransiEnt.Basics.Tables.GasGrid.GenericGasVolumeFlowDataTable (Model for generating a gas volume flow output from a data table).

Information

1. Purpose of model

Average volume flow in Nm3/h from 2009 until 2011 for the Reitbrook Ring-supply line. It has been converted to m3/s.

2. Level of detail, physical effects considered, and physical insight

(Description)

3. Limits of validity

(Description)

4. Interfaces

Modelica RealOutput: y[MSL_combiTimeTable.nout]

Modelica RealOutput: y1

Modelica RealOutput: volume flow rate in [m3/s]

5. Nomenclature

(no elements)

6. Governing Equations

(no equations)

7. Remarks for Usage

(none)

8. Validation

(no validation or testing necessary)

9. References

Source:

Brauer, Thomas ; Schoof, René: Kompaktes 1 MW - PEM - Wasserelektrolysesystem. Regenerativer Wasserstoff für Mobilität und Energiespeicherung. In: NIP Vollversamlung, 2013

10. Version History

(no remarks)



Parameters

TypeNameDefaultDescription
Stringcomplete_relative_path (from GenericDataTable)Functions.fullPathName(Modelica.Utilities.System.getEnvironmentVariable(environment_variable_name) + relativepath)
StringgenericFileName (from GenericDataTable)if use_absolute_path then absolute_path else complete_relative_path
Basics
StringtableName (from GenericDataTable)"default"Table name on file or in function usertab (see docu)
Booleanmultiple_outputs (from GenericDataTable)falseIf set true multiple outputs are enabled (but useage of MultiSum block will fail)
Integer[:]columns (from GenericDataTable)2:size(MSL_combiTimeTable.table, 2)columns of table to be interpolated (*** has to be modified before usage! ***)
Booleanchange_of_sign (from GenericDataTable)falseChange sign of output signal relative to table data
Data location
DataPrivacydatasource (from GenericDataTable)DataPrivacy.isPublicSource of table data
Stringenvironment_variable_name (from GenericDataTable)if datasource == DataPrivacy.isPublic then Types.PUBLIC_DATA else Types.PRIVATE_DATA
Stringrelativepath (from GenericDataTable)""Path relative to source directory
Booleanuse_absolute_path (from GenericDataTable)falseShould only be used for testing purposes
Stringabsolute_path (from GenericDataTable)""
Advanced › table data interpretation
Realconstantfactor (from GenericDataTable)1.0Multiply output with constant factor
Modelica.Blocks.Types.Smoothnesssmoothness (from GenericDataTable)simCenter.tableInterpolationSmoothnessSmoothness of table interpolation
Modelica.Blocks.Types.Extrapolationextrapolation (from GenericDataTable)Modelica.Blocks.Types.Extrapolation.LastTwoPointsExtrapolation of data outside the definition range
Real[:]offset (from GenericDataTable){0}Offsets of output signals
SI.TimestartTime (from GenericDataTable)0
Table data interpretation
Modelica.Units.SI.TimeshiftTime (from GenericDataTable)startTimeShift time of first table column
Modelica.Blocks.Types.TimeEventstimeEvents (from GenericDataTable)Modelica.Blocks.Types.TimeEvents.AtDiscontinuitiesTime event handling of table interpolation

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutput[MSL_combiTimeTable.nout]y (from GenericDataTable)
Modelica.Blocks.Interfaces.RealOutputy1 (from GenericDataTable)
Interfaces.General.VolumeFlowRateOutvalue (from GenericGasVolumeFlowDataTable)

Components

TypeNameDefaultDescription
TransiEnt.SimCentersimCenter (from GenericDataTable)
Modelica.Blocks.Sources.CombiTimeTableMSL_combiTimeTable (from GenericDataTable)
Modelica.Blocks.Math.Gain[MSL_combiTimeTable.nout]sign_changer (from GenericDataTable)