modelTestDryer_L1
Extends from TransiEnt.Basics.Icons.Checkmodel (Icon for check models).
Information
1. Purpose of model
Test environment for the Dryer_L1 model
2. Level of detail, physical effects considered, and physical insight
(Purely technical component without physical modeling.)
3. Limits of validity
(Purely technical component without physical modeling.)
4.Interfaces
(no remarks)
5. Nomenclature
(no elements)
6. Governing Equations
(no equations)
7. Remarks for Usage
(no remarks)
8. Validation
(no validation or testing necessary)
9. References
(no remarks)
10. Version History
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.Basics.Media.Gases.VLE_VDIWA_SG6_var | vle_sg | ||
| TILMedia.VLEFluidTypes.TILMedia_SplineWater | water |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| TransiEnt.Components.Boundaries.Gas.BoundaryRealGas_Txim_flow | source | ||
| TransiEnt.Components.Boundaries.Gas.BoundaryRealGas_pTxi | sink_syngas | ||
| Boundaries.FluidFlow.BoundaryVLE_pTxi | sink_water | ||
| Modelica.Blocks.Sources.Ramp | ramp | ||
| Modelica.Blocks.Sources.Ramp | ramp1 | ||
| Modelica.Blocks.Sources.CombiTimeTable | combiTimeTable | ||
| Modelica.Blocks.Sources.Ramp | ramp2 | ||
| TransiEnt.Components.Gas.GasCleaning.Dryer_L1 | dryer | ||
| Modelica.Blocks.Sources.Ramp | ramp3 | ||
| Modelica.Units.SI.MassFlowRate | m_flow_CH4_in | dryer.gasPortIn.m_flow*inStream(dryer.gasPortIn.xi_outflow[1]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_CH4_out | -(dryer.gasPortOut.m_flow*dryer.gasPortOut.xi_outflow[1]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_CO2_in | dryer.gasPortIn.m_flow*inStream(dryer.gasPortIn.xi_outflow[2]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_CO2_out | -(dryer.gasPortOut.m_flow*dryer.gasPortOut.xi_outflow[2]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_H2O_in | dryer.gasPortIn.m_flow*inStream(dryer.gasPortIn.xi_outflow[3]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_H2O_out | -(dryer.gasPortOut.m_flow*dryer.gasPortOut.xi_outflow[3] + dryer.fluidPortOut.m_flow) | |
| Modelica.Units.SI.MassFlowRate | m_flow_H2_in | dryer.gasPortIn.m_flow*inStream(dryer.gasPortIn.xi_outflow[4]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_H2_out | -(dryer.gasPortOut.m_flow*dryer.gasPortOut.xi_outflow[4]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_CO_in | dryer.gasPortIn.m_flow*inStream(dryer.gasPortIn.xi_outflow[5]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_CO_out | -(dryer.gasPortOut.m_flow*dryer.gasPortOut.xi_outflow[5]) | |
| Modelica.Units.SI.MassFlowRate | m_flow_N2_in | dryer.gasPortIn.m_flow*(1 - sum(inStream(dryer.gasPortIn.xi_outflow))) | |
| Modelica.Units.SI.MassFlowRate | m_flow_N2_out | -(dryer.gasPortOut.m_flow*(1 - sum(dryer.gasPortOut.xi_outflow))) | |
| SimCenter | simCenter |