This model represents a three way valve for real gas flows. It works also for zero flow. It is a modified version of the model ClaRa.Components.VolumesValvesFittings.Valves.ThreeWayValve_L1_simple from ClaRa version 1.3.0. The model is documented there and here only the changes are described.
The two-phase region is deactivated and the valve works for zero flow.
Only valid if changes in density and the two-phase region of the fluid can be neglected.
splitRatio_external: mass fraction in kg/kg
gasPortIn: inlet for real gas
gasPortOut1: outlet for real gas
gasPortOut2: outlet for real gas
eye1
eye2
(no elements)
The mass flow calculation for outlet 1 (eps is the smallest possible number in Modelica) and the composition calculation at the inlet ensure that there is no division by zero for zero mass flow at the inlet.
(no remarks)
(no remarks)
(no remarks)
Model created by Carsten Bode (c.bode@tuhh.de) on Tue Sep 20 2016
Model revised by Carsten Bode (c.bode@tuhh.de) in Apr 2018 (updated to ClaRa 1.3.0)