modelTestJunctions
Extends from TransiEnt.Basics.Icons.Checkmodel (Icon for check models).
Information
Purpose of model:
Test model for the validation of the junctions.
Compare this variables for verification of the split:
Test model of the split:
split1.inlet.m_flow
split1.outlet1.m_flow
split1.outlet2.m_flow
ClaRa model of the split:
splitVLE_L2_Y.inlet.m_flow
splitVLE_L2_Y.outlet1.m_flow
splitVLE_L2_Y.outlet2.m_flow
Test model of the split for reverse flow:
split1.inlet.m_flow
split1.outlet1.m_flow
split1.outlet2.m_flow
The pressures can be checked and compared accordingly.
Compare this variables for the verification of the join:
Test model of the join:
join2.inlet1.m_flow
join2.inlet2.m_flow
join2.outlet.m_flow
ClaRa model of the join:
joinVLE_L2_Y.inlet1.m_flow
joinVLE_L2_Y.inlet2.m_flow
joinVLE_L2_Y.outlet.m_flow
Plausibility check of the junctions:
Look at split3 and check if the mass flow rates of the outlets are equal for the same pressure loss in each pipe
Version History
The model was created by Jan Westphal (j.westphal@tuhh.de) in August 2025