This is a special case of the ASM1 static primary clarifier model.
Here measurement data at the end (effluent) of the preclarifier needs to be provided.
This is typical for some real plants. Influent is then calculated.
Parameters:
V - volume of the preclarifier
aS* - fractions of e.g. COD in influent (soluble components)
aX* - fractions of e.g. COD in influent (particular components)
n_corr- correction factor for the efficiency function
Dimension of InPort is 4.
1 - Chemical Oxygen Demand (COD) at effluent of primary clarifier
2 - nitrate nitrogen (Sno) at effluent of primary clarifier
3 - ammonium nitrogen (Snh) at effluent of primary clarifier
4 - pH-value at effluent of primary clarifier