.WasteWater.ASM1

Information

This library contains components to build models of biological municipal
wastewater treatment plants based on the Activated Sludge Model No.1 (ASM1) by the
International Association on Water Quality (IAWQ) [1,2].


The library currently is structured in following sub-libraries.

 - Interfaces (partial ASM1 models and connectors)
 - PreClar (primary clarifier models)
 - SecClar (several secondary settling tank models)
 - Examples (wastewater treatment plant models)

Main Author:
   Gerald Reichl
   Technische Universitaet Ilmenau
   Faculty of Informatics and Automation
   Department Dynamics and Simulation of ecological Systems
   P.O. Box 10 05 65
   98684 Ilmenau
   Germany
   email: gerald.reichl@tu-ilmenau.de


References:

[1] M. Henze and C.P.L. Grady Jr and W. Gujer and G.v.R. Marais and T. Matsuo:
    Activated Sludge Model No.1. IAWQ, 1987.
[2] M. Henze and W.Gujer and T. Mino and. M.v. Loosdrecht: Activated Sludge
    Models ASM1, ASM2, ASM2d, and ASM3. IWA Task Group on Mathematical Modelling
    for Design and Operation of Biological Wastewater Treatment, 2000.


This package is free software; it can be redistributed and/or modified under the terms of the Modelica license, see the license conditions and the accompanying
disclaimer in the documentation of package Modelica in file "Modelica/package.mo".

Copyright (C) 2000 - 2002, Gerald Reichl

Contents

Name Description
 deni ASM1 denitrification tank
 nitri ASM1 nitrification tank
 SecClarModTakacs Secondary Clarifier ASM1 Model based on Takacs
 blower Blower for the aeration of the nitrification tanks
 pump ASM1 wastewater pump
 FlowSource Flowsource
 WWSource Wastewater source
 EffluentSink Receiving water (river)
 SludgeSink Wastesludge sink
 ControlledDivider2 Controlled flow divider
 divider2 Flowdivider
 mixer2 Mixer of two ASM1 characterised flows
 mixer3 Mixer of 3 ASM1 characterised flows
 sensor_COD Ideal sensor to measure chemical oxygen demand (COD)
 sensor_NH Ideal sensor to measure ammonium nitrogen
 sensor_NO Ideal sensor to measure nitrate nitrogen
 sensor_O2 Ideal sensor to measure dissolved oxygen concentration
 sensor_Q Ideal sensor to measure the flow rate of an ASM1 wastewater stream
 sensor_TKN Ideal TKN and total nitrogen sensor
 sensor_TSS Ideal sensor to measure total suspended solids concentration (ASM1)
 Examples Demonstration examples of the components of the ASM1 library
 Interfaces Connectors and partial ASM1 model for Wastewater Treatment Modelling
 PreClar Primary clarifier modelling based on ASM1
 SecClar Library for secondary settling tank modelling based on ASM1

Generated at 2019-09-17T01:38:12Z by OpenModelicaOpenModelica 1.14.0~dev-26728-gbf603de using GenerateDoc.mos