modelPwLoadVWDepwithVariation

Load with voltage and frequency dependence variation.Developed by AIA. 2016/12/10

Extends from iPSL.Electrical.Essentials.pfComponent (Partial model containing all the Data for entering Power Flow data).

Information

Development level

4

Reference

Eurostag/User's Manual

Last update

2016/12/20 by AIA

Author

RTE-AIA

Contact

modelica@aia.es

This model is a load voltage frequency dependence in witch it allow a variation of the Load P,Q.

Parameters

TypeNameDefaultDescription
RealVo_realV_0*cos(angle_0*Modelica.Constants.pi/180)Initial voltage at node in p.u. (Real part)
RealVo_imgV_0*sin(angle_0*Modelica.Constants.pi/180)Initial voltage at node in p.u. (Imaginary part)
RealstartTimeModelica.Constants.infTime of Load variation
RealP_10New Active reference power
RealQ_10New Reactive reference power
Realvosqrt(Vo_real^2 + Vo_img^2)
Realomega_01
Realalpha0
Realbeta0
Realdelta0
Realgamma0
Power flow data
RealV_b (from pfComponent)400Base voltage of the bus (kV)
RealV_0 (from pfComponent)1Voltage magnitude (pu)
Realangle_0 (from pfComponent)0Voltage angle (deg)
RealP_0 (from pfComponent)1Active power (MW)
RealQ_0 (from pfComponent)0Reactive power (MVAr)
RealS_b (from pfComponent)SysData.S_bSystem base power (MVA)
Realfn (from pfComponent)SysData.fnSystem Frequency (Hz)

Connectors

TypeNameDefaultDescription
iPSL.Connectors.PwPinp
Modelica.Blocks.Interfaces.RealInputomegaRef

Components

TypeNameDefaultDescription
SystemBaseSysData (from pfComponent)Must add this line in all models
Realv
Realaauxiliary variable. Voltage division
Realbauxiliary variable. Frequency division
RealP
RealQ