modelExDoor

Exterior door

Extends from Interfaces.ActiveOnePort (Partial model invoking one bondgraphic connector).

Information

The exterior doors are similar to windows, in that they are thin and homogeneous. Thus the model contains an outside convection layer, no conduction layers, and (unfortunately) no inside convection layer either. This is the same error that the student made in modeling the windows.

Parameters

TypeNameDefaultDescription
Modelica.SIunits.ThermalConductivitylv0.189Specific thermal conductivity of convection outside
Modelica.SIunits.Lengthdxv1Width of convective layer outside
Modelica.SIunits.AreaareaArea of door
Modelica.SIunits.ThermalResistancethvdxv/(lv*area)Thermal resistance of convection outside
RealsfaOrientation of door
Realtilt90Tilt of door
RealOH
RealW
Realabsor0.2Absorption coefficient of door

Connectors

TypeNameDefaultDescription
BondLib.Interfaces.BondConBondCon1 (from ActiveOnePort)Bond graph connector
Modelica.Blocks.Interfaces.RealInput[6]uConnector of Real input signals

Components

TypeNameDefaultDescription
Reale (from ActiveOnePort)Bondgraphic effort
Realf (from ActiveOnePort)Bondgraphic flow
TemperatureTemperature1
SolarPositionSolarPosition1
C1VC1V1
Sources.mSemSe1
Sources.mSfmSf1
Junctions.J0p2J0p2_1
Bonds.fBondB2
Bonds.fBondB1
Bonds.eBondB3
Bonds.eBondB4
Sensors.DeDe1
Bonds.fBondB5
Junctions.J0p4J0p4_1
SolarRadiationSolarRadiation1