recordReformEIRChiller_Trane_CVHF_2300kW_8_10COP_Vanes

ReformEIRChiller Trane CVHF 2300kW/8.10COP/Vanes

A record of Buildings.Fluid.Chillers.Data.ElectricReformulatedEIR.Generic.

Information

Performance data for chiller model. This data corresponds to the following EnergyPlus model:
Chiller:Electric:ReformulatedEIR,
    ReformEIRChiller Trane CVHF 2300kW/8.10COP/Vanes,  !- Name
    2299900,                 !- Reference Capacity {W}
    8.10,                    !- Reference COP {W/W}
    4.44,                    !- Reference Leaving Chilled Water Temperature {C}
    19.58,                   !- Reference Leaving Condenser Water Temperature {C}
    0.07571,                 !- Reference Chilled Water Flow Rate {m3/s}
    0.09085,                 !- Reference Condenser Water Flow Rate {m3/s}
    ReformEIRChiller Trane CVHF 2300kW/8.10COP/Vanes CAPFT,  !- Cooling Capacity Function of Temperature Curve Name
    ReformEIRChiller Trane CVHF 2300kW/8.10COP/Vanes EIRFT,  !- Electric Input to Cooling Output Ratio Function of Temperature Curve Name
    ReformEIRChiller Trane CVHF 2300kW/8.10COP/Vanes EIRFPLR,  !- Electric Input to Cooling Output Ratio Function of Part Load Ratio Curve Name
    0.23,                    !- Minimum Part Load Ratio
    1.04,                    !- Maximum Part Load Ratio
    1.0,                     !- Optimum Part Load Ratio
    0.23,                    !- Minimum Unloading Ratio
    Chilled Water Side Inlet Node,  !- Chilled Water Inlet Node Name
    Chilled Water Side Outlet Node,  !- Chilled Water Outlet Node Name
    Condenser Side Inlet Node,  !- Condenser Inlet Node Name
    Condenser Side Outlet Node,  !- Condenser Outlet Node Name
    1.0,                     !- Compressor Motor Efficiency
    2.0,                     !- Leaving Chilled Water Lower Temperature Limit {C}
    ConstantFlow,            !- Chiller Flow Mode Type
    0.0;                     !- Design Heat Recovery Water Flow Rate {m3/s}

Attributes

NameValue
QEva_flow_nominal-2299900
COP_nominal8.10
PLRMin0.23
PLRMinUnl0.23
PLRMax1.04
mEva_flow_nominal1000*0.07571
mCon_flow_nominal1000*0.09085
TEvaLvg_nominal273.15 + 4.44
TConLvg_nominal273.15 + 19.58
TEvaLvgMin273.15 + 4.44
TEvaLvgMax273.15 + 8.89
TConLvgMin273.15 + 19.58
TConLvgMax273.15 + 34.79
capFunT{4.945951E-02, 1.763194E-02, -1.707908E-03, 8.024411E-02, -2.301455E-03, 2.334434E-03}
EIRFunT{6.870347E-01, 1.176508E-02, 5.473075E-04, 1.235577E-02, 3.200085E-04, -1.378535E-03}
EIRFunPLR{-8.187804E-01, 9.052788E-02, -2.443564E-04, -2.116230E+00, 5.680799E+00, -7.780553E-02, 0.000000E+00, -1.907348E+00, 0.000000E+00, 0.000000E+00}
etaMotor1.0