modelBaseQStatusDangling
Base dynamic model QStatus at terminal 1
Parameters
| Type | Name | Default | Description |
| Boolean | limUQDown10 | | Whether the minimum reactive power limits are reached or not at terminal 1, start value |
| Boolean | limUQUp10 | | Whether the maximum reactive power limits are reached or not at terminal 1, start value |
| QStatus | q1Status0 | | Start voltage regulation status of terminal 1: Standard, AbsorptionMax, GenerationMax |
Components
| Type | Name | Default | Description |
| Boolean | limUQDown1 | | Whether the minimum reactive power limits are reached or not at terminal 1 |
| Boolean | limUQUp1 | | Whether the maximum reactive power limits are reached or not at terminal 1 |
| QStatus | q1Status | | Voltage regulation status of terminal 1: Standard, AbsorptionMax or GenerationMax |