blockDeadBand
Provide a region of zero output
Extends from Modelica.Blocks.Interfaces.SISO (Single Input Single Output continuous control block).
Information
The DeadZone block defines a region of zero output.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Real | EpsMax | UMax | Upper dead band hysteresis |
| Real | EpsMin | -EpsMax | Lower dead band hysteresis |
| Real | UMax | Upper limit of dead band width | |
| Real | UMin | -UMax | Lower limit of dead band width |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| RealInput | u (from SISO) | Connector of Real input signal | |
| RealOutput | y (from SISO) | Connector of Real output signal |