modelEmbeddedPipeVerification
Verification of embedded pipe model for large flow rates
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
This example verifies whether the result temperatures are within reasonable bounds for large and very small flow rates.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.Length | d | 1/(1/(embeddedPipe.RadSlaCha.S_2) + 1/(embeddedPipe.RadSlaCha.S_1)) | Equivalent thickness |
| Modelica.Units.SI.TemperatureDifference | dT | 10 |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| IDEAS.Fluid.HeatExchangers.RadiantSlab.EmbeddedPipe | embeddedPipe | Embedded pipe with multiple discretisations | |
| Sources.MassFlowSource_T | sou | Mass flow source | |
| Modelica.Thermal.HeatTransfer.Sources.FixedTemperature | fixTem | Fixed temperature boundary | |
| Sources.Boundary_pT | sin | Sink | |
| Modelica.Thermal.HeatTransfer.Components.ThermalResistor[embeddedPipe.nDiscr] | theRes1 | Equivalent thermal resistivity of steady state concrete | |
| Modelica.Blocks.Sources.Ramp | ramp | ||
| Modelica.Blocks.Sources.RealExpression | realExpression |
Contents
| Name | Description |
|---|---|
Revisions
-
April 26, 2017 by Filip Jorissen:
Revised implementation for #717.