This block calculates firing angle from desired voltage,
choosing either a linear (Lin) relationship or prescribing the first harmonic (H01) or the root mean square (RMS) .
Since calculating the firing angle from both the H01 and the RMS involves a nonlinear equation,
both relationships have been precalculated and are interpolated from a table.