.Modelica.Mechanics.MultiBody.Sensors.CutForce

Information

The cut-force acting between the two frames to which this model is connected, is determined and provided at the output signal connector force (= frame_a.f). If parameter positiveSign = false, the negative cut-force is provided (= frame_b.f).

Via parameter resolveInFrame it is defined, in which frame the force vector is resolved:

resolveInFrame =
Types.ResolveInFrameA.
Meaning
world Resolve vector in world frame
frame_a Resolve vector in frame_a
frame_resolve Resolve vector in frame_resolve

If resolveInFrame = Types.ResolveInFrameAB.frame_resolve, the conditional connector "frame_resolve" is enabled and output force is resolved in the frame, to which frame_resolve is connected. Note, if this connector is enabled, it must be connected.

In the following figure the animation of a CutForce sensor is shown. The dark blue coordinate system is frame_b, and the green arrow is the cut force acting at frame_b and with negative sign at frame_a.