Generation Group for the example that uses the Anderson-based data
set
Generation Group for the example that uses the Anderson-based
data set.
Instructions
The steps for the correct use of the data sets are indicated
below:
- Drag and Drop an instance of a
OpenIPSL.Data.PowerPlant.GUDynamics record to the
diagram layer of your generation group model.
- Propagate the
GUnitDynamics parameter of the
GUDynamics record.
- Go to the upper-level model that contains an instance of this
generation group (e.g., Anderson
example model). Complete the local instructions and come back to
continue with step 4.
- Insert component references inside the parameter fields of the
Synchronous Machine, Excitation System, Power System Stabilizer and
Turbine/Governor blocks. For example, to specify the inertia
constant of the GENROE synchronous machine (i.e., H), you must fill
its field with this expression:
gUDynamics.guDynamics.machine.H. To do this, you can
either type the value or recreate the whole path, by first clicking
the Insert Component Reference option and then
navigating the references accordingly.
Contents
Generated at 2026-04-14T18:18:34Z by OpenModelicaOpenModelica 1.26.3 using
GenerateDoc.mos