modelIEEE14busLine1to5Opening

Simulation of the opening of line 1 to 5 at t = 1 s

Extends from IEEE14busStaticNetwork (Dynamic model of the IEEE 14-bus system, operating in steady-state).

Components

TypeNameDefaultDescription
PowerGrids.Electrical.SystemsystemPowerGrids (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.ReferenceBusbus1 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus2 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus3 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus4 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus5 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus6 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus7 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus8 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus9 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus10 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus11 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus12 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus13 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Buses.Busbus14 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL1to2 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceWithBreakersL1to5 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL2to3 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL2to4 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL2to5 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL3to4 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL4to5 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL6to11 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL6to12 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL6to13 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL7to8 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL7to9 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL9to10 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL9to14 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL10to11 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL12to13 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.LineConstantImpedanceL13to14 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad2 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad3 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad4 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad5 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad6 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad9 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad10 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad11 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad12 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad13 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Loads.LoadPQVoltageDependenceLoad14 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Banks.CapacitorBankFixedCbank9 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.TransformerFixedRatioT4to7 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.TransformerFixedRatioT4to9 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.TransformerFixedRatioT5to6 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.TransformerFixedRatioTgen1 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.TransformerFixedRatioWithBreakerTgen2 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.TransformerFixedRatioTgen3 (from IEEE14busStaticNetwork)
PowerGrids.Electrical.Branches.TransformerFixedRatioTgen8 (from IEEE14busStaticNetwork)
PowerGrids.Examples.IEEE14bus.ControlledGeneratorIEEEGEN1 (from IEEE14busStaticNetwork)
PowerGrids.Examples.IEEE14bus.ControlledGeneratorIEEEGEN2 (from IEEE14busStaticNetwork)
PowerGrids.Examples.IEEE14bus.SynchronousCondenserGEN3 (from IEEE14busStaticNetwork)
PowerGrids.Examples.IEEE14bus.SynchronousCondenserGEN6 (from IEEE14busStaticNetwork)
PowerGrids.Examples.IEEE14bus.SynchronousCondenserGEN8 (from IEEE14busStaticNetwork)
Modelica.Blocks.Sources.BooleanExpressionL1to5BreakerState