modelPmeter

Power meter, 1-phase

Extends from Partials.Meter2Base (Meter base 2 terminal, 1-phase).

Information

'Meters' are intended as diagnostic instruments. They allow displaying signals both in SI-units or in 'pu'. Use them only when and where needed. Otherwise use 'Sensors'.

Output variable:

  p     power term_p to term_n

Parameters

TypeNameDefaultDescription
Options
Booleanavfalsetime average power
SI.Timetcst1average time-constant
Parameter Scaling
BooleanpuUnits (from Nominal)true= true, if scaled with nom. values (pu), else scaled with 1 (SI)
Nominal
SI.VoltageV_nom (from Nominal)1nominal Voltage (= base for pu)
SI.ApparentPowerS_nom (from Nominal)1nominal Power (= base for pu)

Connectors

TypeNameDefaultDescription
Ports.TwoPin_pterm_p (from Port_p_n)positive terminal
Ports.TwoPin_nterm_n (from Port_p_n)negative terminal

Components

TypeNameDefaultDescription
SIpu.Powerp
SIpu.Powerp_avpav