modelLoadBase
Load base, 3-phase dq0
Extends from Ports.Yport_p (AC one port Y topology 'positive'), Common.Nominal.Nominal (Units and nominal values).
Parameters
| Type | Name | Default | Description |
| Boolean | use_pq_in | false | = true to use input signal pq_in, otherwise use parameter pq0 |
| SIpu.Power | pq0 | {sqrt(3), 1}/2 | fixed {active, reactive} power (start value if use_pq_in) |
| SIpu.Resistance | r_n | 0 | resistance neutral to grd |
| Parameter Scaling |
| Boolean | puUnits (from Nominal) | true | = true, if scaled with nom. values (pu), else scaled with 1 (SI) |
| Nominal |
| SI.Voltage | V_nom (from Nominal) | 1 | nominal Voltage (= base for pu) |
| SI.ApparentPower | S_nom (from Nominal) | 1 | nominal Power (= base for pu) |
| Initialization |
| Types.Dynamics | dynType | system.dynType | transient or steady-state model |