modelReactiveShuntNonSym
Shunt reactor with parallel conductor non symmetric, 3-phase dq0
Extends from Partials.ShuntBaseNonSym (Shunt base non symmetric, 3-phase dq0).
Information
Reactive shunt with general reactance matrix and parallel conductor, defined in abc inertial system.
Use only if 'non symmetric' is really desired because this component needs a time dependent transform of the coefficient matrix.
Info see package ACdq0.Impedances.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SIpu.Conductance | g | {0, 0, 0} | conductance abc (parallel) |
| SIpu.Resistance | r | {0, 0, 0} | resistance abc (serial) |
| SIpu.Reactance | x | [1, 0, 0; 0, 1, 0; 0, 0, 1] | reactance abc |
| Parameter Scaling | |||
| Boolean | puUnits (from Nominal) | true | = true, if scaled with nom. values (pu), else scaled with 1 (SI) |
| Nominal | |||
| SI.Voltage | V_nom (from Nominal) | 1 | nominal Voltage (= base for pu) |
| SI.ApparentPower | S_nom (from Nominal) | 1 | nominal Power (= base for pu) |
| SI.Frequency | f_nom (from NominalAC) | system.f_nom | nominal frequency |
| Initialization | |||
| Types.Dynamics | dynType (from ShuntBase) | system.dynType | transient or steady-state model |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Ports.ACdq0_p | term (from Port_p) | positive terminal |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| PS.Voltage | v (from ShuntBase) | ||
| PS.Current | i (from ShuntBase) | ||
| SI.MagneticFlux | psi_x | magnetic flux |