recordSynchron3rd

Synchronous machine 3rd order parameters

Extends from Base.Units.NominalDataAC (Units and nominal data AC).

Information

Equivalent circuit on diagram layer!

This simplified model uses only main but no transient reactances.

Parameters

TypeNameDefaultDescription
Booleanneu_isofalseisolated neutral if Y
Integerpp1pole-pair number
Integerexcite1excitation (1:el, 2:pm, 3:reluctance)
SIpu.MagneticFluxpsi_pm1.2magnetisation (V/V_nom at open term at omega_nom)
SIpu.Reactancex_d1.9syn reactance d-axis
SIpu.Reactancex_q1.77syn reactance q-axis
SIpu.Reactancex_o0.1reactance o-axis
SIpu.Resistancer_s0.005resistance armature
SIpu.Resistancer_n1resistance neutral to grd (if Y)
Nominal
Base.Types.Unitsunits (from Nominal)Types.puSI | pu
SI.VoltageV_nom (from Nominal)1nom Voltage (= base if pu)
SI.ApparentPowerS_nom (from Nominal)1nom Power (= base if pu)
SI.Frequencyf_nom (from NominalDataAC)50nom frequency