recordSynchron3rd_pm

Synchronous machine pm 3rd order parameters

Extends from Base.Units.NominalDataAC (Units and nominal data AC).

Information

Equivalent circuit on diagram layer!

The relation between 'flux induced by permanent magnet' Psi_pm [Wb] and 'magnetisation' psi_pm [pu] is given by the following relation;

  Psi_pm = psi_pm*V_nom/omega_nom
  psi_pm = Psi_pm*omega_nom/V_nom

Parameters

TypeNameDefaultDescription
Booleanneu_isofalseisolated neutral if Y
Integerpp2pole-pair number
Integerexcite2excitation (2:pm)
SIpu.MagneticFluxpsi_pm1.2magnetisation (V/V_nom at open term at omega_nom)
SIpu.Reactancex_d0.4syn reactance d-axis
SIpu.Reactancex_q0.4syn reactance q-axis
SIpu.Reactancex_o0.1reactance 0-axis
SIpu.Resistancer_s0.05resistance armature
SIpu.Resistancer_n1resistance neutral to grd (if Y)
Nominal
Base.Types.Unitsunits (from Nominal)Types.puSI | pu
SI.VoltageV_nom (from Nominal)1nom Voltage (= base if pu)
SI.ApparentPowerS_nom (from Nominal)1nom Power (= base if pu)
SI.Frequencyf_nom (from NominalDataAC)50nom frequency