modelImpedHeat

Impedance base with heat port, 3-phase dqo

Extends from ImpedBase (Impedance base, 3-phase dqo), Base.Interfaces.AddHeat (Additional heat port).

Information

Same as ImpedBase, but contains an additional heat port.

Does not contain mass and specific heat. These parameters are expected to belong to the corresponding thermal model. The heat-flow at the connector is given by the total dissipated electric energy of all conductors.

Parameters

TypeNameDefaultDescription
BooleanstIni_en (from ImpedBase)trueenable steady-state initial equation
Nominal
Base.Types.Unitsunits (from Nominal)Types.puSI | pu
SI.VoltageV_nom (from Nominal)1nom Voltage (= base if pu)
SI.ApparentPowerS_nom (from Nominal)1nom Power (= base if pu)
SI.Frequencyf_nom (from NominalAC)system.f_nomnom frequency

Connectors

TypeNameDefaultDescription
Base.Interfaces.ACdqo_pterm_p (from Port_p_n)positive terminal
Base.Interfaces.ACdqo_nterm_n (from Port_p_n)negative terminal
Base.Interfaces.Thermal_nheat (from AddHeat)heat port

Components

TypeNameDefaultDescription
SI.Voltagev (from ImpedBase)
SI.Currenti (from ImpedBase)
Modelica.SIunits.Conversions.NonSIunits.Temperature_degCT (from AddHeat)Temperature of conductor
SI.HeatFlowRateQ_flow (from AddHeat)Dissipated heat of conductor