modelPmeter
Power meter, 3-phase dqo
Extends from Partials.Meter2Base (Meter 2 terminal base, 3-phase dqo).
Information
'Meters' are intended as diagnostic instruments. They allow displaying signals in alternative representations, both in SI-units or in 'pu'.
Use them only when and where needed. Otherwise use 'Sensors'.
Output variables:
p {AC active, AC reactive, DC} power term_p to term_n
Optional output variables:
p_av power term_p to term_n, time tau average of p
Comment on the sign-definition of reactive power see ACdqo.Sensors.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Options | |||
| Boolean | av | false | time average power |
| SI.Time | tcst | 1 | average time-constant |
| Integer | signalTrsf (from Sensor2Base) | 0 | signal in which reference frame? |
| Boolean | abc (from Meter2Base) | false | abc inertial |
| Boolean | phasor (from Meter2Base) | false | phasor |
| Nominal | |||
| Base.Types.Units | units (from Nominal) | Types.pu | SI | pu |
| SI.Voltage | V_nom (from Nominal) | 1 | nom Voltage (= base if pu) |
| SI.ApparentPower | S_nom (from Nominal) | 1 | nom Power (= base if pu) |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Base.Interfaces.ACdqo_p | term_p (from Port_p_n) | positive terminal | |
| Base.Interfaces.ACdqo_n | term_n (from Port_p_n) | negative terminal |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SIpu.Power | p | ||
| SIpu.Power | p_av | pav |