modelArcBreaker
Arc voltage for breakers
Extends from Partials.ArcBase (Arc voltage base).
Information
Structurally incomplete model. Use only as component within Breaker kernel.
The 'arc voltage vs current' characteristic is a hyperbolic tangent.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SI.ElectricFieldStrength | E | av electric field arc | |
| Real | r | = R0/(d*Earc), R0 small signal resistance |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| SI.Voltage | v (from ArcBase) | ||
| SI.Current | i (from ArcBase) | ||
| SI.Distance | d | contact distance |