.SpotExamples.g_GenerationACabc.TurbineGenerator

Information

Second example 'from voltage source to generator model' with additional turbine.

Lower part of example (for comparison with and interpretation of upper part):
simplest generator description as a "voltage behind reactance".

Upper part: 3-winding generator model, isotrope with x_d = x_q.
Instead of a fixed power-angle as in the previous example, a turbine delivers the appropriate power. The correspondence is still:

  V_gen1.alpha0 ~ generator.powerAngle (mod 2pi)
  V_gen1.v0     ~ exciter.v_f

In both cases the terminal voltage is fixed by the bus voltage. The results should coincide.

See and compare for example:

 sensor.p[1:2]      active and reactive power
 V_gen1.alpha0 with gen.powerAngle.