modelSummary

Model for performance evaluation

Extends from ClaRa.Basics.Icons.RecordIcon.

Parameters

TypeNameDefaultDescription
RealHeatEngineEfficiency0.4Factor to multiply with electric fan demand during discharge for account for less energy quality of heat compared to el. power
BooleanP2H2PCasetrueTrue for Re-electrification (penalty for power consumption during discharge only in this case)

Components

TypeNameDefaultDescription
SI.HeatFlowRateQ_flow_loss_systemtransmission heat loss of air system
SI.HeatFlowRateE_flow_loss_air2environmentconvective heat loss of air system
SI.PowerP_loss_conv_fanConversion loss at fan
SI.PowerP_loss_conv_heaterConversion loss at heater
SI.PowerP_loss_standbyStandby loss
SI.HeatFlowRateE_flow_loss_hrsgadditional loss in hrsg via blow down
SI.PowerQ_flow_boilertransferred heat in HRSG
SI.EnergyU_theoTheoretical Thermal Storage Capacity
SI.EnergyU_startInitial Thermal Storage Capacity
SI.PowerP_elETES electrical power
RealchargeOperation Mode Charge
RealdischargeOperation Mode Disharge
RealholdOperation Mode Hold
SI.EnergyW_el_c
SI.EnergyW_el_d
SI.EnergyW_el_h
SI.EnergyW_el
SI.EnergyQ_boiler
SI.EnergyQ_boiler_d
SI.EnergyQ_loss_system
SI.EnergyE_loss_air2environment
SI.EnergyE_loss_conv_fan
SI.EnergyE_loss_conv_heater
SI.EnergyE_loss_standby
SI.EnergyE_loss_hrsg
SI.EnergyInputEnergyenergy input
SI.EnergyOutputEnergyenergy output
Realetaenergetic efficiency
RealstandbyLossStandby Loss or electric Work demand during hold
RealsystemTransmissionHeatLossrelative Heat Loss of Total system
RealsystemConvectionHeatLossrelative Heat Loss of Total system
RealselfConsumptionself consumption at discharge, energy consumed at discharge as power
RealconversionLossconversion Loss in Fan and electric Heater
RealaddLossHrsglosses of HRSG via blow down flow
RealequivalentFullCyclesfull cycles of ETES System
RealselfDischargeRateself discharge rate for energy storage system in % per day