| Types.ApparentPowerModule | SNom (from ParamsREEC) | | Nominal apparent power in MVA |
| Types.CurrentModulePu | Id0Pu (from ParamsREEC) | | Start value of d-component current at injector terminal in pu (generator convention) (base SNom, UNom) |
| Types.CurrentModulePu | Iq0Pu (from ParamsREEC) | | Start value of q-component current at injector terminal in pu (generator convention) (base SNom, UNom) |
| Types.PerUnit | PF0 (from ParamsREEC) | | Start value of power factor |
| Types.ActivePowerPu | PConv0Pu (from ParamsREEC) | | Start value of active power at converter terminal in pu (generator convention) (base SNom) |
| Types.ReactivePowerPu | QConv0Pu (from ParamsREEC) | | Start value of reactive power at converter terminal in pu (generator convention) (base SNom) |
| Types.VoltageModulePu | UInj0Pu (from ParamsREEC) | | Start value of voltage magnitude at injector terminal in pu (base UNom) |
| Types.ComplexPerUnit | s0Pu (from ParamsREEC) | | Start value of complex apparent power at terminal in pu (base SnRef) (receptor convention) |
| Types.ComplexVoltagePu | u0Pu (from ParamsREEC) | | Start value of complex voltage at terminal in pu (base UNom) |
| Types.VoltageModulePu | UConv0Pu (from ParamsREEC) | | Start value of voltage module at converter terminal in pu (base UNom) |
| Types.ComplexPerUnit | uConv0Pu (from ParamsREEC) | | Start value of complex voltage at converter terminal in pu (base UNom) |
| Types.ComplexCurrentPu | i0Pu | | Start value of complex current at terminal in pu (base UNom, SnRef) (receptor convention) |
| Types.ComplexPerUnit | iConv0Pu | | Start value of complex current at converter terminal in pu (base UNom, SNom) (generator convention) |
| Types.ActivePowerPu | PInj0Pu | | Start value of active power at injector terminal in pu (generator convention) (base SNom) |
| Types.ReactivePowerPu | QInj0Pu | | Start value of reactive power at injector terminal in pu (generator convention) (base SNom) |
| Types.ComplexPerUnit | uInj0Pu | | Start value of complex voltage at injector in pu (base UNom) |
| Types.Angle | UPhaseConv0 | | Value of voltage phase angle at converter terminal in rad |
| PLL |
| Types.PerUnit | KiPLL (from ParamsPLL) | | PLL integrator gain |
| Types.PerUnit | KpPLL (from ParamsPLL) | | PLL proportional gain |
| Types.AngularVelocityPu | OmegaMaxPu (from ParamsPLL) | | Upper frequency limit in pu (base omegaNom) |
| Types.AngularVelocityPu | OmegaMinPu (from ParamsPLL) | | Lower frequency limit in pu (base omegaNom) |
| Electrical Control › REEC |
| Boolean | PfFlag (from ParamsREEC) | | Power factor flag: Q control (0) or pf control(1) |
| Boolean | PQFlag (from ParamsREEC) | | Q/P priority: Q priority (0) or P priority (1) |
| Boolean | QFlag (from ParamsREEC) | | Q control flag: const. pf or Q ctrl (0) or voltage/Q (1) |
| Boolean | VFlag (from ParamsREEC) | | Voltage control flag: voltage control (0) or Q ctrl (1) |
| Types.VoltageModulePu | Dbd1Pu (from ParamsREEC) | | Overvoltage deadband for reactive current injection in pu (base UNom) (typical: -0.1..0) |
| Types.VoltageModulePu | Dbd2Pu (from ParamsREEC) | | Undervoltage deadband for reactive current injection in pu (base UNom) (typical: 0..0.1) |
| Types.PerUnit | DPMaxPu (from ParamsREEC) | | Active power upper rate limit in pu/s (base SNom) (typical: > 0.1, set to 99 to disable) |
| Types.PerUnit | DPMinPu (from ParamsREEC) | | Active power lower rate limit in pu/s (base SNom) (typical: < -0.1, set to -99 to disable) |
| Types.CurrentModulePu | IMaxPu (from ParamsREEC) | | Maximal apparent current magnitude in pu (base UNom, SNom) (typical: 1..2) |
| Types.PerUnit | Iqh1Pu (from ParamsREEC) | | Maximum reactive current injection (typical: 1..1.1) in pu (base UNom, SNom) |
| Types.PerUnit | Iql1Pu (from ParamsREEC) | | Minimum reactive current injection (typical: -1.1..-1) in pu (base UNom, SNom) |
| Types.PerUnit | Kqi (from ParamsREEC) | | Integrator gain local reactive power PI controller |
| Types.PerUnit | Kqp (from ParamsREEC) | | Proportional gain local reactive power PI controller |
| Types.PerUnit | Kqv (from ParamsREEC) | | K-Factor, reactive current injection gain (typical: 0..10) |
| Types.PerUnit | Kvi (from ParamsREEC) | | Integrator gain local voltage PI controller |
| Types.PerUnit | Kvp (from ParamsREEC) | | Proportional gain local voltage PI controller |
| Types.ActivePowerPu | PMaxREECPu (from ParamsREEC) | | Active power upper limit in REEC in pu (base SNom) (typical: 1) |
| Types.ActivePowerPu | PMinREECPu (from ParamsREEC) | | Active power lower limit in REEC in pu (base SNom) (typical: 0) |
| Types.ReactivePowerPu | QMaxREECPu (from ParamsREEC) | | Reactive power upper limit, when vFlag == 1 in REEC in pu (base SNom) |
| Types.ReactivePowerPu | QMinREECPu (from ParamsREEC) | | Reactive power lower limit, when vFlag == 1 in REEC in pu (base SNom) |
| Types.Time | tIq (from ParamsREEC) | | Filter time constant reactive current in s(typical: 0.01..0.02) |
| Types.Time | tRv (from ParamsREEC) | | Filter time constant terminal voltage in s(typical: 0.01..0.02) |
| Types.Time | tpREEC (from ParamsREEC) | | Active power filter time constant in REEC in s (typical: 0.1..0.2) |
| Types.Time | tPord (from ParamsREEC) | | Filter time constant inverter active power in s |
| Types.VoltageModulePu | VDipPu (from ParamsREEC) | | Low voltage condition trigger voltage for FRT in pu (base UNom) (typical: 0..0.9) |
| Types.VoltageModulePu | VMaxPu (from ParamsREEC) | | Maximum voltage at inverter terminal in pu (base UNom) (typical: 1.05..1.15) |
| Types.VoltageModulePu | VMinPu (from ParamsREEC) | | Minimum voltage at inverter terminal in pu (base UNom) (typical: 0.85..0.95) |
| Types.VoltageModulePu | VRef0Pu (from ParamsREEC) | | Reference voltage for reactive current injection in pu (base UNom) (typical: 0.95..1.05) |
| Types.VoltageModulePu | VUpPu (from ParamsREEC) | | High voltage condition trigger voltage for FRT in pu (base UNom) (typical: 1.1..1.3) |
| Electrical Control › REECb |
| Types.VoltageModulePu | VRef1Pu (from ParamsREECb) | | User-defined reference/bias on the inner-loop voltage control in pu (base UNom) (typical: 0 pu) |
| Generator Converter › REGC |
| Types.PerUnit | IqrMaxPu (from ParamsREGC) | | Maximum rate-of-change of reactive current after fault in pu (base UNom, SNom) (typical: 1..999) |
| Types.PerUnit | IqrMinPu (from ParamsREGC) | | Minimum rate-of-change of reactive current after fault in pu (base UNom, SNom) (typical: -999..-1) |
| Types.PerUnit | RrpwrPu (from ParamsREGC) | | Active current (or power if RateFlag = true) recovery rate in pu/s (base UNom, SNom) (typical: 1..20) |
| Types.Time | tFilterGC (from ParamsREGC) | | Filter time constant of terminal voltage in s(Cannot be set to zero, typical: 0.02..0.05) |
| Generator Converter › REGCa |
| Types.Time | tG (from ParamsREGCa) | | Emulated delay in converter controls in s(Cannot be zero, typical: 0.02..0.05) |
| Types.PerUnit | brkpt (from ParamsREGCa) | | LVPL breakpoint in pu (base UNom) |
| Types.PerUnit | lvpl1 (from ParamsREGCa) | | LVPL gain breakpoint in pu |
| Boolean | Lvplsw (from ParamsREGCa) | | Low voltage power logic switch: 1-enabled/0-disabled |
| Types.PerUnit | zerox (from ParamsREGCa) | | LVPL zero crossing in pu (base UNom) |