modelWPP4BCurrentSource2015

Extends from Dynawo.Electrical.Wind.IEC.BaseClasses.BaseWPP (Base model for Wind Power Plants from IEC 61400-27-1 standard), Dynawo.Electrical.Controls.IEC.IEC61400.Parameters.QControlParameters2015.

Parameters

TypeNameDefaultDescription
Types.ApparentPowerModuleSNom (from BaseWPP)Nominal converter apparent power in MVA
Types.TimetS (from BaseWPP)Integration time step in s
CurrentLimitTables
RealTableIpMaxUwt11 (from CurrentLimitParameters)0
RealTableIpMaxUwt12 (from CurrentLimitParameters)0
RealTableIpMaxUwt21 (from CurrentLimitParameters)0.1
RealTableIpMaxUwt22 (from CurrentLimitParameters)0
RealTableIpMaxUwt31 (from CurrentLimitParameters)0.15
RealTableIpMaxUwt32 (from CurrentLimitParameters)1
RealTableIpMaxUwt41 (from CurrentLimitParameters)0.9
RealTableIpMaxUwt42 (from CurrentLimitParameters)1
RealTableIpMaxUwt51 (from CurrentLimitParameters)0.925
RealTableIpMaxUwt52 (from CurrentLimitParameters)1
RealTableIpMaxUwt61 (from CurrentLimitParameters)1.075
RealTableIpMaxUwt62 (from CurrentLimitParameters)1.0001
RealTableIpMaxUwt71 (from CurrentLimitParameters)1.1
RealTableIpMaxUwt72 (from CurrentLimitParameters)1.0001
Real[:,:]TableIpMaxUwt (from CurrentLimitParameters)[TableIpMaxUwt11, TableIpMaxUwt12; TableIpMaxUwt21, TableIpMaxUwt22; TableIpMaxUwt31, TableIpMaxUwt32; TableIpMaxUwt41, TableIpMaxUwt42; TableIpMaxUwt51, TableIpMaxUwt52; TableIpMaxUwt61, TableIpMaxUwt62; TableIpMaxUwt71, TableIpMaxUwt72]Voltage dependency of active current limits
RealTableIqMaxUwt11 (from CurrentLimitParameters)0
RealTableIqMaxUwt12 (from CurrentLimitParameters)0
RealTableIqMaxUwt21 (from CurrentLimitParameters)0.1
RealTableIqMaxUwt22 (from CurrentLimitParameters)0
RealTableIqMaxUwt31 (from CurrentLimitParameters)0.15
RealTableIqMaxUwt32 (from CurrentLimitParameters)1
RealTableIqMaxUwt41 (from CurrentLimitParameters)0.9
RealTableIqMaxUwt42 (from CurrentLimitParameters)1
RealTableIqMaxUwt51 (from CurrentLimitParameters)0.925
RealTableIqMaxUwt52 (from CurrentLimitParameters)0.33
RealTableIqMaxUwt61 (from CurrentLimitParameters)1.075
RealTableIqMaxUwt62 (from CurrentLimitParameters)0.33
RealTableIqMaxUwt71 (from CurrentLimitParameters)1.1
RealTableIqMaxUwt72 (from CurrentLimitParameters)1
RealTableIqMaxUwt81 (from CurrentLimitParameters)1.1001
RealTableIqMaxUwt82 (from CurrentLimitParameters)1
Real[:,:]TableIqMaxUwt (from CurrentLimitParameters)[TableIqMaxUwt11, TableIqMaxUwt12; TableIqMaxUwt21, TableIqMaxUwt22; TableIqMaxUwt31, TableIqMaxUwt32; TableIqMaxUwt41, TableIqMaxUwt42; TableIqMaxUwt51, TableIqMaxUwt52; TableIqMaxUwt61, TableIqMaxUwt62; TableIqMaxUwt71, TableIqMaxUwt72; TableIqMaxUwt81, TableIqMaxUwt82]Voltage dependency of reactive current limits
GridProtectionTables
RealTabletUoverUwtfilt11 (from GridProtectionParameters)1
RealTabletUoverUwtfilt12 (from GridProtectionParameters)0.33
RealTabletUoverUwtfilt21 (from GridProtectionParameters)1.5
RealTabletUoverUwtfilt22 (from GridProtectionParameters)0.33
RealTabletUoverUwtfilt31 (from GridProtectionParameters)2
RealTabletUoverUwtfilt32 (from GridProtectionParameters)0.33
RealTabletUoverUwtfilt41 (from GridProtectionParameters)2.01
RealTabletUoverUwtfilt42 (from GridProtectionParameters)0.33
RealTabletUoverUwtfilt51 (from GridProtectionParameters)2.02
RealTabletUoverUwtfilt52 (from GridProtectionParameters)0.33
RealTabletUoverUwtfilt61 (from GridProtectionParameters)2.03
RealTabletUoverUwtfilt62 (from GridProtectionParameters)0.33
RealTabletUoverUwtfilt71 (from GridProtectionParameters)2.04
RealTabletUoverUwtfilt72 (from GridProtectionParameters)0.33
RealTabletUoverUwtfilt81 (from GridProtectionParameters)2.05
RealTabletUoverUwtfilt82 (from GridProtectionParameters)0.33
Real[:,:]TabletUoverUwtfilt (from GridProtectionParameters)[TabletUoverUwtfilt11, TabletUoverUwtfilt12; TabletUoverUwtfilt21, TabletUoverUwtfilt22; TabletUoverUwtfilt31, TabletUoverUwtfilt32; TabletUoverUwtfilt41, TabletUoverUwtfilt42; TabletUoverUwtfilt51, TabletUoverUwtfilt52; TabletUoverUwtfilt61, TabletUoverUwtfilt62; TabletUoverUwtfilt71, TabletUoverUwtfilt72; TabletUoverUwtfilt81, TabletUoverUwtfilt82]Disconnection time versus over voltage lookup table
RealTabletUunderUwtfilt11 (from GridProtectionParameters)0
RealTabletUunderUwtfilt12 (from GridProtectionParameters)0.33
RealTabletUunderUwtfilt21 (from GridProtectionParameters)0.5
RealTabletUunderUwtfilt22 (from GridProtectionParameters)0.33
RealTabletUunderUwtfilt31 (from GridProtectionParameters)1
RealTabletUunderUwtfilt32 (from GridProtectionParameters)0.33
RealTabletUunderUwtfilt41 (from GridProtectionParameters)1.01
RealTabletUunderUwtfilt42 (from GridProtectionParameters)0.33
RealTabletUunderUwtfilt51 (from GridProtectionParameters)1.02
RealTabletUunderUwtfilt52 (from GridProtectionParameters)0.33
RealTabletUunderUwtfilt61 (from GridProtectionParameters)1.03
RealTabletUunderUwtfilt62 (from GridProtectionParameters)0.33
RealTabletUunderUwtfilt71 (from GridProtectionParameters)1.04
RealTabletUunderUwtfilt72 (from GridProtectionParameters)0.33
Real[:,:]TabletUunderUwtfilt (from GridProtectionParameters)[TabletUunderUwtfilt11, TabletUunderUwtfilt12; TabletUunderUwtfilt21, TabletUunderUwtfilt22; TabletUunderUwtfilt31, TabletUunderUwtfilt32; TabletUunderUwtfilt41, TabletUunderUwtfilt42; TabletUunderUwtfilt51, TabletUunderUwtfilt52; TabletUunderUwtfilt61, TabletUunderUwtfilt62; TabletUunderUwtfilt71, TabletUunderUwtfilt72]Disconnection time versus under voltage lookup table
RealTabletfoverfwtfilt11 (from GridProtectionParameters)1
RealTabletfoverfwtfilt12 (from GridProtectionParameters)0.33
RealTabletfoverfwtfilt21 (from GridProtectionParameters)1.5
RealTabletfoverfwtfilt22 (from GridProtectionParameters)0.33
RealTabletfoverfwtfilt31 (from GridProtectionParameters)2
RealTabletfoverfwtfilt32 (from GridProtectionParameters)0.33
RealTabletfoverfwtfilt41 (from GridProtectionParameters)2.01
RealTabletfoverfwtfilt42 (from GridProtectionParameters)0.33
Real[:,:]Tabletfoverfwtfilt (from GridProtectionParameters)[Tabletfoverfwtfilt11, Tabletfoverfwtfilt12; Tabletfoverfwtfilt21, Tabletfoverfwtfilt22; Tabletfoverfwtfilt31, Tabletfoverfwtfilt32; Tabletfoverfwtfilt41, Tabletfoverfwtfilt42]Disconnection time versus over frequency lookup table
RealTabletfunderfwtfilt11 (from GridProtectionParameters)0
RealTabletfunderfwtfilt12 (from GridProtectionParameters)0.33
RealTabletfunderfwtfilt21 (from GridProtectionParameters)0.5
RealTabletfunderfwtfilt22 (from GridProtectionParameters)0.33
RealTabletfunderfwtfilt31 (from GridProtectionParameters)1
RealTabletfunderfwtfilt32 (from GridProtectionParameters)0.33
RealTabletfunderfwtfilt41 (from GridProtectionParameters)1.01
RealTabletfunderfwtfilt42 (from GridProtectionParameters)0.33
RealTabletfunderfwtfilt51 (from GridProtectionParameters)1.02
RealTabletfunderfwtfilt52 (from GridProtectionParameters)0.33
RealTabletfunderfwtfilt61 (from GridProtectionParameters)1.03
RealTabletfunderfwtfilt62 (from GridProtectionParameters)0.33
Real[:,:]Tabletfunderfwtfilt (from GridProtectionParameters)[Tabletfunderfwtfilt11, Tabletfunderfwtfilt12; Tabletfunderfwtfilt21, Tabletfunderfwtfilt22; Tabletfunderfwtfilt31, Tabletfunderfwtfilt32; Tabletfunderfwtfilt41, Tabletfunderfwtfilt42; Tabletfunderfwtfilt51, Tabletfunderfwtfilt52; Tabletfunderfwtfilt61, Tabletfunderfwtfilt62]Disconnection time versus under frequency lookup table
PControlTables
RealTablePwpBiasfwpFiltCom11 (from PControlParameters)0.95
RealTablePwpBiasfwpFiltCom12 (from PControlParameters)1
RealTablePwpBiasfwpFiltCom21 (from PControlParameters)1
RealTablePwpBiasfwpFiltCom22 (from PControlParameters)0
RealTablePwpBiasfwpFiltCom31 (from PControlParameters)1.05
RealTablePwpBiasfwpFiltCom32 (from PControlParameters)-1
RealTablePwpBiasfwpFiltCom41 (from PControlParameters)1.06
RealTablePwpBiasfwpFiltCom42 (from PControlParameters)-1
RealTablePwpBiasfwpFiltCom51 (from PControlParameters)1.07
RealTablePwpBiasfwpFiltCom52 (from PControlParameters)-1
RealTablePwpBiasfwpFiltCom61 (from PControlParameters)1.08
RealTablePwpBiasfwpFiltCom62 (from PControlParameters)-1
RealTablePwpBiasfwpFiltCom71 (from PControlParameters)1.09
RealTablePwpBiasfwpFiltCom72 (from PControlParameters)-1
Real[:,:]TablePwpBiasfwpFiltCom (from PControlParameters)[TablePwpBiasfwpFiltCom11, TablePwpBiasfwpFiltCom12; TablePwpBiasfwpFiltCom21, TablePwpBiasfwpFiltCom22; TablePwpBiasfwpFiltCom31, TablePwpBiasfwpFiltCom32; TablePwpBiasfwpFiltCom41, TablePwpBiasfwpFiltCom42; TablePwpBiasfwpFiltCom51, TablePwpBiasfwpFiltCom52; TablePwpBiasfwpFiltCom61, TablePwpBiasfwpFiltCom62; TablePwpBiasfwpFiltCom71, TablePwpBiasfwpFiltCom72]Table for defining power variation versus frequency
QLimitTables
RealTableQMaxUwtcFilt11 (from QLimitParameters)0
RealTableQMaxUwtcFilt12 (from QLimitParameters)0
RealTableQMaxUwtcFilt21 (from QLimitParameters)0.001
RealTableQMaxUwtcFilt22 (from QLimitParameters)0
RealTableQMaxUwtcFilt31 (from QLimitParameters)0.8
RealTableQMaxUwtcFilt32 (from QLimitParameters)0.33
RealTableQMaxUwtcFilt41 (from QLimitParameters)1.2
RealTableQMaxUwtcFilt42 (from QLimitParameters)0.33
RealTableQMaxUwtcFilt51 (from QLimitParameters)1.21
RealTableQMaxUwtcFilt52 (from QLimitParameters)0.33
RealTableQMaxUwtcFilt61 (from QLimitParameters)1.22
RealTableQMaxUwtcFilt62 (from QLimitParameters)0.33
Real[:,:]TableQMaxUwtcFilt (from QLimitParameters)[TableQMaxUwtcFilt11, TableQMaxUwtcFilt12; TableQMaxUwtcFilt21, TableQMaxUwtcFilt22; TableQMaxUwtcFilt31, TableQMaxUwtcFilt32; TableQMaxUwtcFilt41, TableQMaxUwtcFilt42; TableQMaxUwtcFilt51, TableQMaxUwtcFilt52; TableQMaxUwtcFilt61, TableQMaxUwtcFilt62]Voltage dependency of reactive power maximum limit
RealTableQMinUwtcFilt11 (from QLimitParameters)0
RealTableQMinUwtcFilt12 (from QLimitParameters)0
RealTableQMinUwtcFilt21 (from QLimitParameters)0.001
RealTableQMinUwtcFilt22 (from QLimitParameters)0
RealTableQMinUwtcFilt31 (from QLimitParameters)0.8
RealTableQMinUwtcFilt32 (from QLimitParameters)-0.33
RealTableQMinUwtcFilt41 (from QLimitParameters)1.2
RealTableQMinUwtcFilt42 (from QLimitParameters)-0.33
Real[:,:]TableQMinUwtcFilt (from QLimitParameters)[TableQMinUwtcFilt11, TableQMinUwtcFilt12; TableQMinUwtcFilt21, TableQMinUwtcFilt22; TableQMinUwtcFilt31, TableQMinUwtcFilt32; TableQMinUwtcFilt41, TableQMinUwtcFilt42]Voltage dependency of reactive power minimum limit
RealTableQMaxPwtcFilt11 (from QLimitParameters)0
RealTableQMaxPwtcFilt12 (from QLimitParameters)0
RealTableQMaxPwtcFilt21 (from QLimitParameters)0.001
RealTableQMaxPwtcFilt22 (from QLimitParameters)0
RealTableQMaxPwtcFilt31 (from QLimitParameters)0.3
RealTableQMaxPwtcFilt32 (from QLimitParameters)0.33
RealTableQMaxPwtcFilt41 (from QLimitParameters)1
RealTableQMaxPwtcFilt42 (from QLimitParameters)0.33
Real[:,:]TableQMaxPwtcFilt (from QLimitParameters)[TableQMaxPwtcFilt11, TableQMaxPwtcFilt12; TableQMaxPwtcFilt21, TableQMaxPwtcFilt22; TableQMaxPwtcFilt31, TableQMaxPwtcFilt32; TableQMaxPwtcFilt41, TableQMaxPwtcFilt42]Active power dependency of reactive power maximum limit
RealTableQMinPwtcFilt11 (from QLimitParameters)0
RealTableQMinPwtcFilt12 (from QLimitParameters)0
RealTableQMinPwtcFilt21 (from QLimitParameters)0.001
RealTableQMinPwtcFilt22 (from QLimitParameters)0
RealTableQMinPwtcFilt31 (from QLimitParameters)0.3
RealTableQMinPwtcFilt32 (from QLimitParameters)-0.33
RealTableQMinPwtcFilt41 (from QLimitParameters)1
RealTableQMinPwtcFilt42 (from QLimitParameters)-0.33
Real[:,:]TableQMinPwtcFilt (from QLimitParameters)[TableQMinPwtcFilt11, TableQMinPwtcFilt12; TableQMinPwtcFilt21, TableQMinPwtcFilt22; TableQMinPwtcFilt31, TableQMinPwtcFilt32; TableQMinPwtcFilt41, TableQMinPwtcFilt42]Active power dependency of reactive power minimum limit
Electrical
Types.PerUnitBesPu (from BaseWPP)Shunt susceptance in pu (base UNom, SNom)
Types.PerUnitGesPu (from BaseWPP)Shunt conductance in pu (base UNom, SNom)
Types.PerUnitResPu (from BaseWPP)Serial resistance in pu (base UNom, SNom)
Types.PerUnitXesPu (from BaseWPP)Serial reactance in pu (base UNom, SNom)
Control
Types.PerUnitDipMaxPu (from BaseWPP)Maximum active current ramp rate in pu/s (base UNom, SNom) (generator convention)
Types.PerUnitDiqMaxPu (from BaseWPP)Maximum reactive current ramp rate in pu/s (base UNom, SNom) (generator convention)
Types.PerUnitDiqMinPu (from BaseWPP)Minimum reactive current ramp rate in pu/s (base UNom, SNom) (generator convention)
Types.PerUnitKipaw (from BaseWPP)Anti-windup gain for active current in pu/s (base UNom, SNom)
Types.PerUnitKiqaw (from BaseWPP)Anti-windup gain for reactive current in pu/s (base UNom, SNom)
Types.TimetG (from BaseWPP)Current generation time constant in s
PLL
Types.TimetPll (from BaseWPP)PLL first order filter time constant in s
Types.VoltageModulePuUPll1Pu (from BaseWPP)Voltage below which the angle of the voltage is filtered and possibly also frozen, in pu (base UNom)
Types.VoltageModulePuUPll2Pu (from BaseWPP)Voltage below which the angle of the voltage is frozen, in pu (base UNom) (UPll2Pu < UPll1Pu typically)
PControl
Types.PerUnitKpaw (from BaseWPP)Anti-windup gain for active power in pu/s (base SNom)
Types.PerUnitDPMaxP4BPuMaximum WT power ramp rate in pu/s (base SNom) (generator convention)
Types.TimetPAeroAerodynamic power response time constant in s
Types.TimetPOrdP4BPower order lag time constant in s
Types.TimetUFiltP4BFilter time constant for voltage measurement in s
CurrentLimiter
Types.CurrentModulePuIMaxDipPu (from BaseWPP)Maximum current during voltage dip at converter terminal in pu (base UNom, SNom)
Types.CurrentModulePuIMaxPu (from BaseWPP)Maximum continuous current at converter terminal in pu (base UNom, SNom)
Types.PerUnitKpqu (from BaseWPP)Partial derivative of reactive current limit against voltage in pu (base UNom, SNom)
BooleanMdfsLim (from BaseWPP)Limitation of type 3 stator current (false: total current limitation, true: stator current limitation)
BooleanMqpri (from BaseWPP)Prioritization of reactive power during FRT (false: active power priority, true: reactive power priority)
Types.VoltageModulePuUpquMaxPu (from BaseWPP)WT voltage in the operation point where zero reactive power can be delivered, in pu (base UNom)
Types.TimetUFiltclVoltage filter time constant in s
QControl
Types.PerUnitIqH1Pu (from BaseWPP)Maximum reactive current injection during dip in pu (base UNom, SNom) (generator convention)
Types.PerUnitIqMaxPu (from BaseWPP)Maximum reactive current injection in pu (base UNom, SNom) (generator convention)
Types.PerUnitIqMinPu (from BaseWPP)Minimum reactive current injection in pu (base UNom, SNom) (generator convention)
Types.PerUnitIqPostPu (from BaseWPP)Post-fault reactive current injection in pu (base UNom, SNom) (generator convention)
Types.PerUnitKiq (from BaseWPP)Reactive power PI controller integration gain in pu/s (base UNom, SNom)
Types.PerUnitKiu (from BaseWPP)Voltage PI controller integration gain in pu/s (base UNom, SNom)
Types.PerUnitKpq (from BaseWPP)Reactive power PI controller proportional gain in pu (base UNom, SNom)
Types.PerUnitKpu (from BaseWPP)Voltage PI controller proportional gain in pu (base UNom, SNom)
Types.PerUnitKqv (from BaseWPP)Voltage scaling factor for FRT current in pu (base UNom, SNom)
IntegerMqG (from BaseWPP)General Q control mode (0-4): Voltage control (0), Reactive power control (1), Open loop reactive power control (2), Power factor control (3), Open loop power factor control (4)
Types.PerUnitRDropPu (from BaseWPP)Resistive component of voltage drop impedance in pu (base UNom, SNom)
Types.TimetPost (from BaseWPP)Length of time period where post-fault reactive power is injected, in s
Types.TimetQord (from BaseWPP)Reactive power order lag time constant in s
Types.VoltageModulePuUMaxPu (from BaseWPP)Maximum voltage in voltage PI controller integral term in pu (base UNom)
Types.VoltageModulePuUMinPu (from BaseWPP)Minimum voltage in voltage PI controller integral term in pu (base UNom)
Types.VoltageModulePuUqDipPu (from BaseWPP)Voltage threshold for UVRT detection in Q control in pu (base UNom)
Types.VoltageModulePuURef0Pu (from BaseWPP)User-defined bias in voltage reference in pu (base UNom)
Types.PerUnitXDropPu (from BaseWPP)Inductive component of voltage drop impedance in pu (base UNom, SNom)
IntegerMqUvrtUVRT Q control modes (0-2) (see Table 23, section 5.6.5.7, page 51 of the IEC norm N°61400-27-1:2015)
Types.TimetPFiltQActive power filter time constant in s
Types.TimetUFiltQVoltage filter time constant in s
Types.VoltageModulePuUdb1PuVoltage dead band lower limit in pu (base UNom)
Types.VoltageModulePuUdb2PuVoltage dead band upper limit in pu (base UNom)
QLimiter
BooleanQlConst (from BaseWPP)True if limits are constant
Types.ReactivePowerPuQMaxPu (from BaseWPP)Constant maximum reactive power at grid terminal in pu (base SNom) (generator convention)
Types.ReactivePowerPuQMinPu (from BaseWPP)Constant minimum reactive power at grid terminal in pu (base SNom) (generator convention)
Types.TimetPFiltqlFilter time constant for active power measurement in s
Types.TimetUFiltqlFilter time constant for voltage measurement in s
GridProtection
Types.PerUnitfOverPu (from BaseWPP)WT over frequency protection activation threshold in pu (base fNom)
Types.PerUnitfUnderPu (from BaseWPP)WT under frequency protection activation threshold in pu (base fNom)
Types.VoltageModulePuUOverPu (from BaseWPP)WT over voltage protection activation threshold in pu (base UNom)
Types.VoltageModulePuUUnderPu (from BaseWPP)WT under voltage protection activation threshold in pu (base UNom)
PControlWP
Types.PerUnitDPRefMaxPu (from BaseWPP)Maximum positive ramp rate for PD power reference in pu/s (base SNom)
Types.PerUnitDPRefMinPu (from BaseWPP)Minimum negative ramp rate for PD power reference in pu/s (base SNom)
Types.PerUnitDPwpRefMaxPu (from BaseWPP)Maximum positive ramp rate for WP power reference in pu/s (base SNom)
Types.PerUnitDPwpRefMinPu (from BaseWPP)Minimum negative ramp rate for WP power reference in pu/s (base SNom)
Types.PerUnitKiwpp (from BaseWPP)Power PI controller integration gain in pu/s (base SNom)
Types.PerUnitKpwpp (from BaseWPP)Power PI controller proportional gain in pu (base SNom)
Types.PerUnitKwppRef (from BaseWPP)Power reference gain in pu (base SNom)
Types.ActivePowerPuPKiwppMaxPu (from BaseWPP)Maximum active power reference from integration in pu (base SNom)
Types.ActivePowerPuPKiwppMinPu (from BaseWPP)Minimum active power reference from integration in pu (base SNom)
Types.ActivePowerPuPRefMaxPu (from BaseWPP)Maximum PD power reference in pu (base SNom)
Types.ActivePowerPuPRefMinPu (from BaseWPP)Minimum PD power reference in pu (base SNom)
Types.TimetpftLead time constant in the reference value transfer function in s
Types.TimetpfvLag time constant in the reference value transfer function in s
Types.TimetWPfFiltPFilter time constant for frequency measurement in s
Types.TimetWPPFiltPFilter time constant for active power measurement in s
QControlWP
Types.PerUnitDXRefMaxPu (from BaseWPP)Maximum positive ramp rate for WT reactive power or voltage reference in pu/s (base SNom or UNom) (generator convention)
Types.PerUnitDXRefMinPu (from BaseWPP)Minimum negative ramp rate for WT reactive power or voltage reference in pu/s (base SNom or UNom) (generator convention)
Types.PerUnitKiwpx (from BaseWPP)Reactive power or voltage PI controller integral gain in pu/s (base SNom)
Types.PerUnitKpwpx (from BaseWPP)Reactive power or voltage PI controller proportional gain in pu (base SNom)
Types.PerUnitKwpqRef (from BaseWPP)Reactive power reference gain in pu (base SNom)
Types.PerUnitKwpqu (from BaseWPP)Voltage controller cross coupling gain in pu (base SNom)
IntegerMwpqMode (from BaseWPP)Control mode (0 : reactive power reference, 1 : power factor reference, 2 : UQ static, 3 : voltage control)
Types.TimetUqFilt (from BaseWPP)Time constant for the UQ static mode in s
Types.VoltageModulePuUwpqDipPu (from BaseWPP)Voltage threshold for UVRT detection in pu (base UNom)
Types.PerUnitXKiwpxMaxPu (from BaseWPP)Maximum WT reactive power or voltage reference from integration in pu (base SNom or UNom) (generator convention)
Types.PerUnitXKiwpxMinPu (from BaseWPP)Minimum WT reactive power or voltage reference from integration in pu (base SNom or UNom) (generator convention)
Types.PerUnitXRefMaxPu (from BaseWPP)Maximum WT reactive power or voltage reference in pu (base SNom or UNom) (generator convention)
Types.PerUnitXRefMinPu (from BaseWPP)Minimum WT reactive power or voltage reference in pu (base SNom or UNom) (generator convention)
Types.TimetWPPFiltQFilter time constant for active power measurement in s
Types.TimetWPQFiltQFilter time constant for reactive power measurement in s
Types.TimetWPUFiltQFilter time constant for voltage measurement in s
Types.TimetxftLead time constant in the reference value transfer function in s
Types.TimetxfvLag time constant in the reference value transfer function in s
Initialization
Types.ComplexCurrentPui0Pu (from BaseWPP)Initial complex current at grid terminal in pu (base UNom, SnRef) (receptor convention)
Types.PerUnitIGsIm0Pu (from BaseWPP)Initial imaginary component of the current at converter terminal in pu (base UNom, SNom) (generator convention)
Types.PerUnitIGsRe0Pu (from BaseWPP)Initial real component of the current at converter terminal in pu (base UNom, SNom) (generator convention)
Types.PerUnitIpMax0Pu (from BaseWPP)Initial maximum active current at converter terminal in pu (base UNom, SNom) (generator convention)
Types.PerUnitIqMax0Pu (from BaseWPP)Initial maximum reactive current at converter terminal in pu (base UNom, SNom) (generator convention)
Types.PerUnitIqMin0Pu (from BaseWPP)Initial minimum reactive current at converter terminal in pu (base UNom, SNom) (generator convention)
Types.ActivePowerPuPAg0Pu (from BaseWPP)Initial generator (air gap) power in pu (base SNom) (generator convention)
Types.ReactivePowerPuQMax0Pu (from BaseWPP)Initial maximum reactive power at grid terminal in pu (base SNom) (generator convention)
Types.ReactivePowerPuQMin0Pu (from BaseWPP)Initial minimum reactive power at grid terminal in pu (base SNom) (generator convention)
Types.ComplexVoltagePuu0Pu (from BaseWPP)Initial complex voltage at grid terminal in pu (base UNom)
Types.PerUnitUGsIm0Pu (from BaseWPP)Initial imaginary component of the voltage at converter terminal in pu (base UNom)
Types.PerUnitUGsRe0Pu (from BaseWPP)Initial real component of the voltage at converter terminal in pu (base UNom)
Operating point
Types.ActivePowerPuP0Pu (from BaseWPP)Initial active power at grid terminal in pu (base SnRef) (receptor convention)
Types.ReactivePowerPuQ0Pu (from BaseWPP)Initial reactive power at grid terminal in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU0Pu (from BaseWPP)Initial voltage amplitude at grid terminal in pu (base UNom)
Types.AngleUPhase0 (from BaseWPP)Initial voltage angle at grid terminal in rad
Types.PerUnitX0Pu (from BaseWPP)Initial reactive power or voltage reference in pu (base SNom or UNom) (generator convention)
Types.PerUnitXWT0Pu (from BaseWPP)Initial reactive power or voltage reference at grid terminal in pu (base SNom or UNom) (generator convention)
QControlTables
RealTableQwpUErr11 (from QControlParameters2015)-0.05
RealTableQwpUErr12 (from QControlParameters2015)1.21
RealTableQwpUErr21 (from QControlParameters2015)0
RealTableQwpUErr22 (from QControlParameters2015)0.21
RealTableQwpUErr31 (from QControlParameters2015)0.05
RealTableQwpUErr32 (from QControlParameters2015)-0.79
RealTableQwpUErr41 (from QControlParameters2015)0.06
RealTableQwpUErr42 (from QControlParameters2015)-0.79
RealTableQwpUErr51 (from QControlParameters2015)0.07
RealTableQwpUErr52 (from QControlParameters2015)-0.79
RealTableQwpUErr61 (from QControlParameters2015)0.08
RealTableQwpUErr62 (from QControlParameters2015)-0.79
Real[:,:]TableQwpUErr (from QControlParameters2015)[TableQwpUErr11, TableQwpUErr12; TableQwpUErr21, TableQwpUErr22; TableQwpUErr31, TableQwpUErr32; TableQwpUErr41, TableQwpUErr42; TableQwpUErr51, TableQwpUErr52; TableQwpUErr61, TableQwpUErr62]Table for the UQ static mode
UfMeasurement
Types.AngularVelocityPuDfMaxPuMaximum frequency ramp rate in pu/s (base omegaNom)
BooleanMzcZero crossing measurement mode (true = 1 if the wind turbine protection system uses zero crossings to detect the frequency - otherwise false = 0)
Types.TimetfFiltFilter time constant for frequency measurement in s
Types.TimetphiFiltFilter time constant for voltage angle measurement in s
Types.TimetUFiltFilter time constant for voltage measurement in s
Mechanical
Types.PerUnitCdrtPuDrive train damping in pu (base SNom, omegaNom)
Types.TimeHgenGenerator inertia time constant in s
Types.TimeHwtrWT rotor inertia time constant in s
Types.PerUnitKdrtPuDrive train stiffness in pu (base SNom, omegaNom)

Connectors

TypeNameDefaultDescription
Dynawo.Connectors.ACPowerterminal (from BaseWPP)
Modelica.Blocks.Interfaces.RealInputomegaRefPu (from BaseWPP)Reference frame for grid angular frequency in pu (base omegaNom)
Modelica.Blocks.Interfaces.RealInputPWPRefPu (from BaseWPP)Reference active power in pu (base SNom) (generator convention)
Modelica.Blocks.Interfaces.RealInputtanPhi (from BaseWPP)Tangent phi (can be figured as QPu / PPu)
Modelica.Blocks.Interfaces.RealInputQWPRefPuReference reactive power in pu (base SNom) (generator convention)
Modelica.Blocks.Interfaces.RealInputUWPRefPuReference voltage in pu (base UNom) (generator convention)

Components

TypeNameDefaultDescription
Dynawo.Electrical.Controls.IEC.IEC61400.BaseControls.Auxiliaries.ElecMeasurementselecMeasurements (from BaseWPP)
Dynawo.Electrical.Wind.IEC.WT.WT4BCurrentSource2015wT4BCurrentSource
Dynawo.Electrical.Controls.IEC.IEC61400.WPP.WPPControl2015wPPControl2015