Contains switches acting on one conductor only and double-switches acting on both conductors.
Terminology:
Forced switch is used for a component that breaks the current independent of a possible zero crossing.
Switch is used for a component, that breaks the current during zero-crossing but does not contain any additional physical properties like arc-voltage etc.
Breaker is used for a component that acts basically like a 'Switch' but contains additionally physical properties of plasma-arcs, opening duration etc.
| Name | Description |
|---|---|
| ForcedSwitch | Forced switch, 1-phase |
| ForcedCommSwitch | Forced commuting switch, 1-phase |
| Switch | Ideal switch, 1-phase |
| Breaker | Breaker, 1-phase |
| ForcedDoubleSwitch | Forced double switch, 1-phase |
| DoubleSwitch | Double switch, 1-phase |
| DoubleBreaker | Double breaker, 1-phase |
| Partials | Partial models |
| Parameters | Parameter data for interactive use |