recordRXline
RX-line parameters, 1-phase
Extends from Base.Units.NominalDataAC (Units and nominal data AC).
Information
Relations.
x = 2*pi*f_nom*L/R_base reactance r = R / R_base resistance
Coupling.
positive coupled: x0 > x uncoupled limit: x0 = x
More info see package AC1_DC.Impedances.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| SIpu.Resistance | r | {0.1, 0.1}*1e-3 | resistance/km |
| SIpu.Reactance_km | x | 1e-3 | reactance/km |
| SIpu.Reactance_km | x0 | 3*x | reactance/km zero-comp |
| Nominal | |||
| Base.Types.Units | units (from Nominal) | Types.pu | SI | pu |
| SI.Voltage | V_nom (from Nominal) | 1 | nom Voltage (= base if pu) |
| SI.ApparentPower | S_nom (from Nominal) | 1 | nom Power (= base if pu) |
| SI.Frequency | f_nom (from NominalDataAC) | 50 | nom frequency |