modelASMcharacteristic

AC asynchronous machine: torque - slip characteristic

Information

Steady-state simulation to produce motor characteristic 'torque vs slip'.

  asm.torque         motor mechanical torque
  asm.motor.slip     slip (negative: motor, positive: generator mode)

       slip <  -1    motor breake mode
  -1 <  slip <  0     motor drive mode
       slip >  0     generator mode

Plot torque vs slip:
plot 'asm.torque', then right-click 'asm.motor.slip' and choose 'Independent variable': 'asm.motor.slip'.

up users guide

Components

TypeNameDefaultDescription
Spot.Systemsystem
Spot.ACdqo.Nodes.GroundOnegrd
Spot.ACdqo.Sources.Voltagevoltage
Spot.DrivesACdqo.ASMasm
Spot.Common.Thermal.BdCondVbdCond
Spot.Mechanics.Rotation.Speedspeed
Spot.Blocks.Signals.TransientspeedSignal
Data.Machines.Asynchron400V_30kVAasyn400_30k