1. Purpose of model
Highly adaptable but non-physical model for all kinds of energy storages.
2. Level of detail, physical effects considered, and physical insight
(no remarks)
3. Limits of validity
(no remarks)
4. Interfaces
P_set: input for electric power in [W] -Grid side setpoint power (Positive = load request, negative = unload request) [W]
P_is: output for electric power in [W]- Grid side power (Positive = loading, negative = unloading) [W]
5. Nomenclature
(no remarks)
6. Governing Equations
(no remarks)
7. Remarks for Usage
Boolean parameter use_PowerRateLimiter can deactive block 'PowerRateLimiter'. This might lead to faster calculation results if power rate limitation is not needed.
PlantDynamics: Set T_plant to 0 in StorageParameters to deactivate first order block
8. Validation
Tested in check model "TransiEnt.Storage.Base.Check.TestGenericStorage"
9. References
(no remarks)
10. Version History
Model created by Pascal Dubucq (dubucq@tuhh.de) on 01.10.2014
Model adapted by Lisa Andresen (andresen@tuhh.de), Jan 2017
Model adapted by Oliver Schülting (oliver.schuelting@tuhh.de), Jun 2018
Extended from base class by Carsten Bode (c.bode@tuhh.de), Nov 2018
Model adapted by Oliver Schülting (oliver.schuelting@tuhh.de), April 2018: added first order plant dynamics block which can be deactivated