modelType4B_WT_CDV

IEC Type 4B Full-Scale Wind Turbine Model. Developed by DTU

Information

Development level

2

Parameters

TypeNameDefaultDescription
Realw_init1Initial steady state generator speed
RealT_Ufilt0.01Voltage measurement filter time constant
RealdPmax99Wind turbine maximum power ramp rate
RealTpord0.01Time constant in power order lag
RealTpaero0.01Time constant in aerodynamic power response
RealTpfilt0.01Power measurement filter time constant
RealMwttPF1Power factor control mode
RealMwttU0Voltage control mode
RealMwttOL0Open loop mode
RealUref01User defined voltage reference
RealTangent_phi0Calculated from power factor setpoint
RealQmax0.33Maximum reactive power
RealQmin-0.33Minimum reactive power
RealTufilt0.01Voltage measurement filter time constant
RealUqdip0.8Voltage threshold value for LVRT detection
RealTpost1Length of time period where post fault reactive power is injected
RealUdb10.1Voltage dead band lower limit
RealUdb20.1Voltage dead band upper limit
RealKqv4Voltage scaling factor for LVRT current
Realiqh11Maximum reactive current injection during dip
Realiqmin-1.1Minimum reactive current injection
Realiqmax1.1Maximum reactive current injection
Realiq_post-0.2Post fault reactive current injection
RealUmax1.05Maximum voltage in voltage PI controller integral term
RealUmin0Minimum voltage in voltage PI controller integral term
RealKiQ0.1Reactive power PI controller integration gain
RealKpQ1Reactive power PI controller proportional gain
RealTqord0.01Time constant in reactive power order lag
RealKiU0.1Voltage PI controller integration gain
RealKpU1Voltage PI controller proportional gain
RealTiq0.01Time constant in reactive current lag
RealHgen0.7275Inertia Constant of Generator
RealHwtr4.225Inertia Constant of Wind Turbine Rotor
Realk_sh140Drive Train Stiffness
Realc_sh0.8Drive Train Damping
RealT_init0.9Initial Steady State Shaft Torque
Reali_maxdip1.1Maximum current during voltage dip at the wind turbine terminals
Reali_max1.23Maximum continuous current at the wind turbine terminals
RealM_Qpri1Prioritisation of q control during LVRT (0: active power priority - 1: reactive power priority)
RealTg0.005Current generation time constant
RealdiPmax99Maximum active current ramp rate
RealdiQmin-99Minimum reactive current ramp rate
RealdiQmax99Maximum reactive current ramp rate
RealRdroop0Resistive component of voltage drop impedance
RealXdroop0Inductive component of voltage drop impedance
Realini_iPref
Realini_iQref

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealInputUref
Modelica.Blocks.Interfaces.RealInputQref
Modelica.Blocks.Interfaces.RealInputPref
iPSL.Connectors.PwPinWTG_terminal

Components

TypeNameDefaultDescription
iPSL.Electrical.Wind.DTU.CurrentLimiterCurrentLimitationModel
iPSL.Electrical.Sensors.PwPowerMeaspwPowerMeas
iPSL.Electrical.Wind.DTU.DriveTraindriveTrain
iPSL.Electrical.Wind.DTU.GenSet_Type4genSet_Type4_2
iPSL.Electrical.Wind.DTU.QControl_Type4BqControl_Type4B1
iPSL.Electrical.Sensors.PwVoltagepwVoltage
iPSL.Electrical.Wind.DTU.PControl_Type4B_CDVpControl_Type4B_CDV
iPSL.Electrical.Machines.DTU.PwdqCurrentSourcepwdqCurrentSource
iPSL.Electrical.Controls.DTU.pwPLLpwPLL

Revisions

Copyright 2015-2016 RTE (France), SmarTS Lab (Sweden), AIA (Spain) and DTU (Denmark)

The authors can be contacted by email: info@itesla-ipsl.org

This Source Code Form is subject to the terms of the Mozilla Public License, v. 2.0.

If a copy of the MPL was not distributed with this file, You can obtain one at http://mozilla.org/MPL/2.0.