packageBaseClasses
Package with base classes for Buildings.Fluid.HeatExchangers
Extends from Modelica.Icons.BasesPackage (Icon for packages containing base classes).
Information
This package contains base classes that are used to construct the models in Buildings.Fluid.HeatExchangers.
Contents
| Name | Description |
|---|---|
| Header for a heat exchanger register | |
| Register for a heat exchanger | |
| Manifold for a heat exchanger air duct connection | |
| Manifold for duct inlet that distributes the mass flow rate equally | |
| Duct manifold without resistance | |
| Calculates the hA value for water inside a coil | |
| Sensible convective heat transfer model for air to water coil | |
| Calculates an hA value for natural convection around a cylinder | |
| Element of a heat exchanger with humidity condensation of fluid 2 | |
| Element of a heat exchanger with no humidity condensation | |
| Block to compute the latent heat transfer based on the Lewis number | |
| Partial manifold for heat exchanger duct connection | |
| Partial heat exchanger duct and pipe manifold | |
| Partial model to implement heat exchangers based on effectiveness model | |
| Partial model for heat exchanger with effectiveness - NTU relation and no moisture condensation | |
| Element of a heat exchanger 2 | |
| Partial pipe manifold for a heat exchanger | |
| Ideal heater, cooler, humidifier or dehumidifier with prescribed outlet conditions | |
| Pipe manifold for a heat exchanger connection | |
| Manifold for heat exchanger register that distributes the mass flow rate equally | |
| Manifold for heat exchanger register | |
| Calculates the Rayleigh number for a given fluid and characteristic length | |
| Fully dry coil model | |
| Model implementing the switching algorithm of the TK-fuzzy model for cooling coil application | |
| Model that calculates the UA-value from cooling coil data at rated conditions. | |
| Fully wet coil model using esilon_C.mo function | |
| determineWaterIndex | Determine the index of water in a 2-component medium model |
| dynamicViscosityWater | Returns the dynamic viscosity for water |
| epsilon_C | Computes heat exchanger effectiveness for given capacity flow rates and heat exchanger flow regime |
| epsilon_ntuZ | Computes heat exchanger effectiveness for given number of transfer units and heat exchanger flow regime |
| isobaricExpansionCoefficientWater | Returns the isobaric expansion coefficient for water |
| lmtd | Log-mean temperature difference |
| ntu_epsilonZ | Computes number of transfer units for given heat exchanger effectiveness and heat exchanger flow regime |
| prandtlNumberWater | Returns the Prandtl number for water |
| Collection of models that illustrate model use and test models |